Start About ALS Scandinavia Client service Analytical packages ALS Denmark ALS Finland ALS Norway Overview
Environment Work environment Medicine Electronics Foodstuff Industry Pharmaceuticals Isotopes
environment

Search this site
  

ON-LINE
 Customer number:
 
 Password:
  LOGIN
No password?
Activate On-line
 
Other water analyses

 
 
 
Stormwater
pH Pb
conductivity Cu
phosphorus, total Zn
nitrogen, total Cd
suspended solids Cr
  Ni
For methods and limits of quantification for metals, see V-3a for other compounds, please contact the laboratory. Minimum sample volume: 500 ml plastic, 250 ml plastic and 125 ml plastic.

 

 

 

 
 
Car wash water
BOD7 Cu
pH Ni
COD Cr Cd
Oil index Pb
Cr Zn
According to Allmänna råd 96:1 (Swedish EPA). For limits of quantification for metals, see V3-b, for other compounds, please contact the laboratory. Minimum sample volume: 1 l glass, 500 ml plastic and 125 ml plastic.
   
 
 
Corrosivity test for water
pH
conductivity
marble test
alkalinity
ammonium nitrogen
total hardness
calcium
magnesium
chloride
sulfate
Minimum sample volume: 500 ml.
   
 
 
Corrosivity test for soil
pH
conductivity
alkalinity
ammonium nitrogen
calcium
magnesium
chloride
sulfate
Minimum sample amount: 100 g.
   
 
 
Swimming pool water
COD (Mn) 
pH 
turbidity
Minimum sample volume: 500 ml plastic.
   
 
 

Other physical - chemical parameters
Parameter Sample volume (ml)
acidity 100
alkalinity 100
alkalinity, titration 100
ammonium nitrogen 100
BOD7, biochemical oxygen demand, 7 days 500
bromate 250
bromide 100
COD (Cr), chemical oxygen demand 100
COD (Mn), chemical oxygen demand 100
cyanide, easily liberatable* 500
cyanide, total * 500
cyanide, total + easily liberatable * 500
deposit (sediment; visual determination) 500
DOC 100
fluoride 100
phosphate phosphorus 100
phosphorus, total 100
colour 100
silicon, dissolved 100
chloride 100
chlorine, free active 100
chlorine, total active 100
conductivity 100
conductivity (1:1) in solid samples 100 g
nitrogen, total 100
nitrogen, total in solid samples 100 g
nitrogen, total, pulp and paper industry (Devardas) 100 g
odour, art and strength 500
Nitrite/nitrate nitrogen, sum 100
Nitrite nitrogen 100
Nitrate nitrogen (calculated from sum of nitrite/nitrate and nitrite nitrogen) 100
Nitrate nitrogen (ion chromatography) 100
pH 100
pH i sludge 100 g
pH i soil 100 g
salinity (calulated from chloride) 100
sulfate 100
sulfide, clean water¹) 250
sulfide, wastewater¹) 100
sulfide, in solid samples 100 g
sulfite 100
suspended solids 1000
suspended solids and ignition residue 1000
oxygen ¹) 2x120
TOC 100
dry matter 1000
dry matter + ignition residue 1000
turbidity 100
turbidity (visual determination) 500
Please contact the laboratory for information on methods and limits of quantification.
Analyses are partly performed in collaboration with subcontractors. Use plastic bottles for all samples. Bottles may be ordered from the laboratory. When more than one parameter is to be determined, at least 500 ml sample is required.
*For cyanide analyses, use a 500 ml plastic bottle with a NaOH tablet (for preservation).
¹) Winkler bottle + reagent may be ordered from the laboratory.

Additional parameters are available. Please contact the laboratory!

ALS Scandinavia © 2011