Start About ALS Scandinavia Client service Analytical packages ALS Denmark ALS Finland ALS Norway Overview
Environment Work environment Medicine Electronics Foodstuff Industry Pharmaceuticals Isotopes
electronics


Search this site
  

ON-LINE
 Customer number:
 
 Password:
  LOGIN
No password?
Activate On-line
 
Organic compounds in electronics

 
 
 
OE-1 Polycyclic aromatic hydrocarbons (PAH)
in electronics
naphthalene (0.05) chrysene (0.05)
acenaphthylene (0.05) benzo(a)anthracene (0.05)
acenaphthene (0.05) benzo(b)fluoranthene (0.05)
fluorene (0.05) benzo(k)fluoranthene (0.05)
phenanthrene (0.05) benzo(a)pyrene (0.05)
anthracene (0.05) dibenzo(ah)anthracene (0.05)
fluoranthene (0.05) benzo(ghi)perylene (0.05)
pyrene (0.05) indeno(123cd)pyrene (0.05)
 
Figures in brackets denote limits of quantification in mg/kg. Minimum sample amount: 20 g. Method: GC-MS.
 
 
OE-2 Polychlorinated biphenyls (PCB)
in electronics
PCB 28 PCB 138
PCB 52 PCB 153
PCB 101 PCB 180
PCB 118 Sum of 7 PCBs
 
Limit of quantification is 0.003 mg/kg (may vary depending on sample composition). Minimum sample amount: 20 g. Method: GC-MS.
 
 
OE-5 Monoaromatic hydrocarbons
in electronics
benzene ethylbenzene
toluene xylenes
  Limit of quantification is 0.025 mg/kg (may vary depending on sample composition). Minimum sample amount: min 10 g. Method: HS-GC-MS.
 
 
OE-6 Chlorinated aliphatics in electronics
dichloromethane trichloromethane
1,1-dichloroethane tetrachloromethane
1,2-dichloroethane 1,1,1-trichloroethene
cis-dichloroethane 1,1,2-trichloroethene
trans-dichloroethane trichloroethene
1,2-dichloropropane tetrachloroethene
  Limit of quantification is 0.5 mg/kg (may vary depending on sample composition). Minimum sample amount: min 10 g. Method: GC-ECD.
 
 
OE-19 Organotin compounds in electronics
monobutyltin dioctyltin
dibutyltin tricyclohexyltin
tributyltin (TBT) monophenyltin
tetrabutyltin diphenyltin
monooctyltin triphenyltin
  Limit of quantification is 1 µg/kg. (may vary depending on sample composition). Minimum sample amount: min 20 g. Method: GC-AED.
 
 
OE-22 Dioxins and furans in electronics
2,3,7,8-tetraCDD
1,2,3,7,8-pentaCDD
1,2,3,4,7,8-hexaCDD
1,2,3,6,7,8-hexaCDD
1,2,3,7,8,9-hexaCDD
1,2,3,4,6,7,8-heptaCDD
octachlorodibenzodioxin
2,3,7,8-tetraCDF
1,2,3,7,8-pentaCDF
2,3,4,7,8-pentaCDF
1,2,3,4,7,8-hexaCDF
1,2,3,6,7,8-hexaCDF
1,2,3,7,8,9-hexaCDF
2,3,4,6,7,8-hexaCDF
1,2,3,4,6,7,8-heptaCDF
1,2,3,4,7,8,9-heptaCDF
octachlorodibenzofuran
  Limit of quantification is 2-10 ng/kg (may vary depending on sample composition). Minimum sample amount: min 20 g. Method: GC-MS.
 
 
OE-24 Creosotes in electronics
naphthalene (0.05) chrysene (0.05)
acenaphthylene (0.05) benzo(a)anthracene (0.05)
acenaphthene (0.05) benzo(b)fluoranthene (0.05)
fluorene (0.05) benzo(k)fluoranthene (0.05)
phenanthrene (0.05) benzo(a)pyrene (0.05)
anthracene (0.05) dibenzo(ah)anthracene (0.05)
fluoranthene (0.05) benzo(ghi)perylene (0.05)
pyrene (0.05) indeno(123cd)pyrene (0.05)
   
1-methylnaphthalene (0.05) p-cresol (0.1)
2-methylnaphthalene (0.05) dibenzofuran (0.05)
benzo(e)pyrene (0.05) quinoline (0.05)
biphenyl (0.05) carbazol (0.05)
o-cresol (0.1) dibenzothiophene (0.05)
m-cresol (0.1) benzo(k)fluoranthene (0.05)
  Figures in brackets denote limits of quantification in mg/kg. Minimum sample amount: 20 g. Method: GC-MS.
 
 
OE-25 Brominated flame retardants
in electronics
tetraBDE (0.5) diBB (1.0)
BDE 47 (0.05) PBB 15 (0.10)
pentaBDE (0.5) triBB (1.0)
BDE 99 (0.05) tetraBB (0.50)
BDE 100 (0.05) PBB 49 (0.05)
hexaBDE (0.5) PBB 52 (0.05)
heptaBDE (1.0) pentaBB (0.50)
octaBDE (1.0) PBB 101 (0.05)
nonaBDE (1.0) hexaBB (0.05)
decaBDE (5.0) PBB 153 (0.05)
   decaBB (5.0)
Figures in brackets denote limits of quantification in µg/kg (may vary depending on sample composition). Minimum sample amount: 20 g. Method: GC-MSD.
 
Tetrabromobisphenol A
(TBBP-A)
Minimum sample amount: 20 g. Method: Pyrolysis with GC-MS.
 
 
OE-30 CFC and HCFC in electronics
CFC-11 HCFC-21
CFC-12 HCFC-22
CFC-113 HCFC-123
CFC-114 HCFC-141b
CFC-115 HCFC-142b
  Limit of quantification is 20 mg/kg. Minimum sample amount: 10 g. Method: HS-GC-MS.
 
 
OE-31 Halons in electronics
halon 1211 halon 104
halon 1301 halon 1001
halon 2402  
  Limit of quantification is 20 mg/kg. Minimum sample amount: 10 g. Method: HS-GC-MS.
 
 
OE-32 Chlorinated paraffins in electronics
C10-C13 C14-C17

 
 
 
OE-34 Halogens in electronics
Cl F Br
 

Method: ICP-SFMS/ion chromatography.

 
 
Many other compounds can be determined in electronics. Contact the laboratory for information.
ALS Scandinavia © 2010