Organic compounds in electronics
|
|
| |
 |
| |
OE-1 Polycyclic aromatic hydrocarbons (PAH)
in electronics |
| naphthalene (0.05) |
chrysene (0.05) |
| acenaphthylene (0.05) |
benzo(a)anthracene (0.05) |
| acenaphthene (0.05) |
benzo(b)fluoranthene (0.05) |
| fluorene (0.05) |
benzo(k)fluoranthene (0.05) |
| phenanthrene (0.05) |
benzo(a)pyrene (0.05) |
| anthracene (0.05) |
dibenzo(ah)anthracene (0.05) |
| fluoranthene (0.05) |
benzo(ghi)perylene (0.05) |
| pyrene (0.05) |
indeno(123cd)pyrene (0.05) |
|
|
| Figures in brackets denote limits of quantification in mg/kg. Minimum sample amount: 20 g. Method: GC-MS. |
|
| |
 |
| |
OE-2 Polychlorinated biphenyls (PCB)
in electronics |
| PCB 28 |
PCB 138 |
| PCB 52 |
PCB 153 |
| PCB 101 |
PCB 180 |
| PCB 118 |
Sum of 7 PCBs |
|
|
| Limit of quantification is 0.003 mg/kg (may vary depending on sample composition). Minimum sample amount: 20 g. Method: GC-MS. |
|
| |
 |
| |
OE-5 Monoaromatic hydrocarbons
in electronics |
| benzene |
ethylbenzene |
| toluene |
xylenes |
|
|
Limit of quantification is 0.025 mg/kg (may vary depending on sample composition). Minimum sample amount: min 10 g. Method: HS-GC-MS. |
| |
 |
| |
| OE-6 Chlorinated aliphatics in electronics |
| dichloromethane |
trichloromethane |
| 1,1-dichloroethane |
tetrachloromethane |
| 1,2-dichloroethane |
1,1,1-trichloroethene |
| cis-dichloroethane |
1,1,2-trichloroethene |
| trans-dichloroethane |
trichloroethene |
| 1,2-dichloropropane |
tetrachloroethene |
|
|
Limit of quantification is 0.5 mg/kg (may vary depending on sample composition). Minimum sample amount: min 10 g. Method: GC-ECD. |
| |
 |
| |
| OE-19 Organotin compounds in electronics |
| monobutyltin |
dioctyltin |
| dibutyltin |
tricyclohexyltin |
| tributyltin (TBT) |
monophenyltin |
| tetrabutyltin |
diphenyltin |
| monooctyltin |
triphenyltin |
|
|
Limit of quantification is 1 µg/kg. (may vary depending on sample composition). Minimum sample amount: min 20 g. Method: GC-AED. |
| |
 |
| |
| OE-22 Dioxins and furans in electronics |
| 2,3,7,8-tetraCDD |
| 1,2,3,7,8-pentaCDD |
| 1,2,3,4,7,8-hexaCDD |
| 1,2,3,6,7,8-hexaCDD |
| 1,2,3,7,8,9-hexaCDD |
| 1,2,3,4,6,7,8-heptaCDD |
| octachlorodibenzodioxin |
| 2,3,7,8-tetraCDF |
| 1,2,3,7,8-pentaCDF |
| 2,3,4,7,8-pentaCDF |
| 1,2,3,4,7,8-hexaCDF |
| 1,2,3,6,7,8-hexaCDF |
| 1,2,3,7,8,9-hexaCDF |
| 2,3,4,6,7,8-hexaCDF |
| 1,2,3,4,6,7,8-heptaCDF |
| 1,2,3,4,7,8,9-heptaCDF |
| octachlorodibenzofuran |
|
|
Limit of quantification is 2-10 ng/kg (may vary depending on sample composition). Minimum sample amount: min 20 g. Method: GC-MS. |
| |
 |
| |
| OE-24 Creosotes in electronics |
| naphthalene (0.05) |
chrysene (0.05) |
| acenaphthylene (0.05) |
benzo(a)anthracene (0.05) |
| acenaphthene (0.05) |
benzo(b)fluoranthene (0.05) |
| fluorene (0.05) |
benzo(k)fluoranthene (0.05) |
| phenanthrene (0.05) |
benzo(a)pyrene (0.05) |
| anthracene (0.05) |
dibenzo(ah)anthracene (0.05) |
| fluoranthene (0.05) |
benzo(ghi)perylene (0.05) |
| pyrene (0.05) |
indeno(123cd)pyrene (0.05) |
| |
|
| 1-methylnaphthalene (0.05) |
p-cresol (0.1) |
| 2-methylnaphthalene (0.05) |
dibenzofuran (0.05) |
| benzo(e)pyrene (0.05) |
quinoline (0.05) |
| biphenyl (0.05) |
carbazol (0.05) |
| o-cresol (0.1) |
dibenzothiophene (0.05) |
| m-cresol (0.1) |
benzo(k)fluoranthene (0.05) |
|
|
Figures in brackets denote limits of quantification in mg/kg. Minimum sample amount: 20 g. Method: GC-MS. |
| |
 |
| |
OE-25 Brominated flame retardants
in electronics |
| tetraBDE (0.5) |
diBB (1.0) |
| BDE 47 (0.05) |
PBB 15 (0.10) |
| pentaBDE (0.5) |
triBB (1.0) |
| BDE 99 (0.05) |
tetraBB (0.50) |
| BDE 100 (0.05) |
PBB 49 (0.05) |
| hexaBDE (0.5) |
PBB 52 (0.05) |
| heptaBDE (1.0) |
pentaBB (0.50) |
| octaBDE (1.0) |
PBB 101 (0.05) |
| nonaBDE (1.0) |
hexaBB (0.05) |
| decaBDE (5.0) |
PBB 153 (0.05) |
| |
decaBB (5.0) |
Figures in brackets denote limits of quantification in µg/kg (may vary depending on sample composition). Minimum sample amount: 20 g. Method: GC-MSD. |
|
|
Tetrabromobisphenol A
(TBBP-A) |
| Minimum sample amount: 20 g. Method: Pyrolysis with GC-MS. |
|
| |
 |
| |
| OE-30 CFC and HCFC in electronics |
| CFC-11 |
HCFC-21 |
| CFC-12 |
HCFC-22 |
| CFC-113 |
HCFC-123 |
| CFC-114 |
HCFC-141b |
| CFC-115 |
HCFC-142b |
|
|
Limit of quantification is 20 mg/kg. Minimum sample amount: 10 g. Method: HS-GC-MS. |
| |
 |
| |
| OE-31 Halons in electronics |
| halon 1211 |
halon 104 |
| halon 1301 |
halon 1001 |
| halon 2402 |
|
|
|
Limit of quantification is 20 mg/kg. Minimum sample amount: 10 g. Method: HS-GC-MS. |
| |
 |
| |
| OE-32 Chlorinated paraffins in electronics |
| C10-C13 |
C14-C17 |
|
|
|
|
|
| |
 |
| |
| OE-34 Halogens in electronics |
| Cl |
F |
Br |
|
|
|
|
Method: ICP-SFMS/ion chromatography. |
| |
 |
| |
|
|